Outline and
features
Realized multifunctional indications, the expanded flow rate range, the
high-accuracy measurement and the improved durability, by loading a
microcomputerized counting unit on a rotary piston type flow meter of the
simplest structure among all positive displacement flow meters.
* Realized the high measuring accuracy of ¡Þ 0.2%.
* Easy to measure high viscosity liquids, due to a small pressure loss.
* Allows the user to change settings in the field by operating the
switches on the front surface of the counting unit.
Applications
* Measurement management
and control of various kinds of fluids, such as foods and chemical solutions
Main specifications
Size
|
25A,40A,50A,80A,100A
|
Flow
range
|
200(special
spec.: 40) - 50,000L/h
|
Viscosity
|
0.5-500mPas
|
Special
spec. (0.3-30,000mPas)
|
Temperature
|
-10
to 80 deg C
|
Special
spec. (-10 to 150 deg C)
|
Pressure
|
Working
pressure-less than 1.0MPa
|
Special
spec. (Less than 2.0MPa)
|
Accuracy
|
Within
+-0.2%
|
Special
spec. (within +-0.5%)
|
Indication
|
*Total
integrated flow rate
|
*Instantaneous
flow rate ( /h) or ( /min)
|
*Integrated
flow rate (Resettable)
|
*Instantaneous
flow rate (%)
|
*Alarm
for excessive flow
|
*Alarm
for high flow
|
*Alarm
for low flow
|
*Alarm
for battery
|
Output
signal
|
*Analog:
4-20mADC
|
*Pulse,
alarm: voltage contactless or open collector
|
Material
|
FC200/CAC406
|
FC200/FC200
|
FC200/SCS14
|
SCS14/SCS14
|
Construction
|
Field
totalizing type: Instinct-safe type Exia IIBT4
|
Signal
output type: Explosion-proof and frame-proof type Exd IIBT4X
|
Hãy