Flow Body (ALCM 00300 to ALCM 03000) |
Process Connections |
Female threads, G½" adapters for flanges (ANSI and DIN), dairy or tri-clamp® |
Operating pressure |
max. 5000 psig (350 bar) |
Process temperature |
up to 260 °F (125°C) |
Material |
SS as per DIN 1.4571 (AISI 316 Ti) |
Repeatability |
0.33% for liquid, 0.5% for gas, 0.83% for insertion |
Housing protecton |
IP67 |
Electrical connection |
9-pin flange plug - compact version with integral transmitter |
Max cable length |
100' (30 M) beween tranducer and transmitter |
Ex-protection |
EX II 2G EEx ib IIC T2-T4 |
Housing protection |
IP65; IP67; IP68 |
Ex-protection |
Exid ⅡB T4; Exib ⅡC T 4 |
Weight |
ALCM 00300 and 03000: 11-22 lbs (5-10 kg)
ALCM 06000 and 60000: 22-88 lbs (10-40 kg) |
Flowbody (ALCM 06000 to ALCM 6000) |
Process Connections |
Flanges acc. EN 1092, ANSI B16.5, DIN2512 |
Nominal pressure |
PN 40, ANSI 150 / 300 lbs |
Process temperature |
-40°F to +356°F ( -40°C to +180°C) |
Ambient temperature |
-40°F to +140°F (-40°C to +60°C) |
Enclosure protection |
NEMA 4X (IP 65) (EN60529) |
Materials |
Flow tubes, splitter flanges: 1.4404(316 L)/1.4571(316 Ti) |
Housing material |
Cast iron |
Ex-protection |
EX II 2G EEx ib IIC T2-T4 |
|
|
Transmitter |
LCD Display(illuminated) |
2-line alpha numerical, measured values & parameter settings, 2x 20 characters (2.4X 4.7 mm) |
Programming |
Via front keypad |
Supply voltage |
24 VDC, ±15% |
Power Consumption |
Max. 2 W |
Interface |
RS-485 |
Weights |
3.3 lbs (1.5 kg) wall mount, 2.2 lbs (1 kg) panel mount |
Housing Wall & Panel |
Plastic with transparent cover |
Operating temperature |
32 to 122 °F (0 to 50 °C) |
Ex protection |
EX II (2) G (Eex ib) IIC |
Temperature drift |
0.05% per 10 K load (Load>10 k) |
Voltage outputs |
two 0-5VDC, resolution: 12 bits, linearity ±0.05% final |
Current outputs |
(1) 0/4-20mA, active,
galvanically free, 12 bits resolution with linearity: ±0.05% of final
value, Load ≤ 800 Ω scaled output of flow rate, or job total, density
or temperature |
Pulse outputs |
Proportional to flow rate, 8-5 kHz, adjustable via jumper, push/pull: Imax-0mA open collector: Vce ≤ 30V, Ice ≤ 50 mA. |
Switch outputs |
adjustable via jumper;
push/pull: Imax 20mA. Open Collector: Vce ≤ 30V, Ice ≤ 50 mA, 1 or 2
job total, fault or rate or cycle |
Switch inputs |
passive "on" >4VDC, "off" <1VDC; total, reset,& offset | |